Exabyte 4-Pin Diagnostic Cable

The Exabyte 8200, 8500, 8500c, and some 8505 and 8205 drives have a 4-pin
monitor port on the rear panel of the drive.  To perform various serial
functions on the drive, the 4-pin Diagnostic Cable will need to be connected.
When used with the CTSMON utility, the Diagnostic Cable can very useful
for documenting integration problems as well as configuring the "8500"
family of 8mm products.

Connector and pin layout:

Exabyte Diagnostic Cable pn 303771: 4-pin ELCO to DB9
***********************************************************
* ELCO-8283                          DB9-Female           *
***********************************************************
*  Pin 1     ...is connected to...    Pin 5  (gnd)        *
*  Pin 2     ...is connected to...    Pin 2  (-Txd)       *
*  Pin 3     ...is connected to...    Pin 3  (-Rxd)       *
*                                     Connect Pins 4,6,8  *
***********************************************************



Exabyte Diagnostic Cable pn 727005: 4-pin ELCO to DB25
***********************************************************
* ELCO-8283                          DB25Female           *
***********************************************************
*  Pin 1     ...is connected to...    Pin 7  (gnd)        *
*  Pin 2     ...is connected to...    Pin 3  (-Txd)       *
*  Pin 3     ...is connected to...    Pin 2  (-Rxd)       *
*                                     Connect Pins 5,6,20 *
***********************************************************


Cables are available from Direct Sales.  Contact Exabyte Direct Service 
Sales at (800) 392-8273 or (303) 471-7791.