Safehouse Alarm  (490-0470)         Features            Faxback Doc. # 8102

Four Burglar Alarm Trigger Loops - 3 instant and 1 delayed alarm loops are
available with each loop having 2 totally separate circuits. 2 are N.O.
and N.C. loops. These loops operate independently of each other. It's as
if you had 4 separate alarm systems.

Fire Alarm Loop - for 4-wire smoke detectors and 2-wire heat sensors.

Momentary Contact - Panic/Tamper Loop - This additional loop can be
connected to N.O. switches or sensing devices and will activate the
alarm center anytime. This is ideal for panic/tamper switches or 24 hour
protection of property inside the house. When this loop is violated,
the entire alarm center is automatically armed.

Battery Back-Up - The batteries will give you up to 3.5 hours of armed
operation or 2 complete alarm cycles (5 minutes each), in case of a
power failure. The system requires rechargeable gel batteries, which are 
automatically recharged inside the panel.

Automatic Alarm Reset - The alarm center will activate for 5 minutes, when
a loop is violated, and then reset for future operation. The alarm center
will reset in that case as long as at least one of the remaining loops is
not violated. Each burglar loop works independently of the others and will
cause the alarm to sound if violated and will reset if the violation has
been removed.

Note - the fire alarm must be manually reset, it will continue to sound
until this is done.

Remote Arm/Disarm Connections - Up to 10 remote switches, for arming and
disarming the alarm center, can be connected anywhere you like.

Entry Exit Delay - The entry and exit delay times are independently
adjustable (0 to 45 seconds). This will give you time to get out of the 
premises after arming the alarm center and time to disarm it after
entering the premises.

Pre-Alarm Circuit - This circuit will activate a buzzer during the entry 
delay time, to remind you to disarm the alarm center. Use of this circuit
is optional. It will not work if the delay time is set to 0.

Day Loop Sounder - uses the same sounder as the pre-alarm but acts as an 
announcer for opening doors, etc. on the day instant loop or zone.
Sounds as long as door is open.

External Alarm Output - Powers 12V DC alarm devices (such as a bell,
siren or strobe light), rated up to 2 amp total. Two individual outputs,
one for burglar and one for fire.

Battery Test Led - Indicates the condition of the batteries, when the
battery test button is pressed.

Loop Led - This indicator lights when all loops are intact. There are
connections for remote loop leds for use with remote arm/disarm
installations.  This led blinks during the entry delay time, as a visual
reminder to disarm the alarm center.

Arm Led - This led lights when the alarm center is armed and blinks when
the alarm has been triggered. It will continue to blink until you disarm
the alarm center. This warns you there has been an alarm condition while
you where away. An alarm led can be included in a remote arm/disarm
installation, also.

AC Power Led - Lights when AC power is present.

Auxiliary Output - Provides a constant 12V Dc output to power Auxiliary 
devices.

Dry Contact Terminals - An internal N.O. relay, connected to these
terminals, will close when the alarm center activates. This relay can be
used as a switch to turn on a device that has its own power supply.

Fire circuit - for wired smoke detectors and heat sensors. Uses an End of
Line Module to supervise the circuits for integrity, power and alarm
condition. Can be manually reset at the panel only. Has separate trouble
sounder and dialer outputs.


(RLR/jlc-03/22/94)