Remote Control  (490-0796)     Optional Equipment       Faxback Doc. # 8890
Alarm System

The system has contacts that can be used to turn on optional alarm sounding
or other gimmick and devices when the system is triggered.  These contacts
provide no power, they are simply switches.

*  To connect a device that is triggered by a normally open switch (the
   switch closes when the alarm sounds), connect its lead between Terminals
   4 and 5.  To connect a device that is triggered by a normally closed
   switch (the switch opens when the alarm sounds), connect its lead
   between Terminals 5 and 6.

Note:  For devices that require high-current loads, use larger gauge wire
       and an inline fuse.

Connecting Additional Devices

The control module's Terminal 14 provides 12 volts of DC power up to 300
milliamps when the system is armed.  You can use this to provide power to
other sensing devices for additional protection.

(RLR/jlc-03/22/94)