300 BPS DCM-2 Modem (260-1173)    Specifications       Faxback Doc. # 5982

COMPATIBILITY:                       RECEIVER SENSITIVITY: -49 dBm
        MODEM: Bell 103                    TRANSMIT LEVEL: -10 dBm, +/- 1 dBm
       DIALER: Tandy Command              TONE DIAL LEVEL: N/A
   DATA RATES: 300 bps                     LINE IMPEDANCE: 600 Ohms nominal
 SPEED SELECT: Automatic               RINGER EQUIVALENCE: 0.7 B
   CMD BUFFER: N/A                             MODULATION:
      SPEAKER: On                                300 BAUD: Frequency Shift
 DATA FORMATS: 8 bit, no parity; 7 bit                     Keyed (FSK)
               even, odd or no parity.            DIALING: Pulse (10/20 pps)
TESTING MODES: Local loopback,                             Tone 10 characters
               Remote loopback.                            per second)

(css 08/04/93)